53 54
8. The double pump station
The double pump station ensures a continuous circulation of the glycol inside the closed solar loop
when useful energy is available in the solar panels. The double pump station recommended by
RM Solar is constructed so as to be unaffected by the operating temperatures of the loop for many
years.
8.1 Technical data:
Maximum working excess pressure: 6 bar
Safety valve: 6 bar
Circulation pump: Solar Circulating Pump
Nominal voltage: AC 230 V
Power consumption: Speed 1 45 W
Speed 2 65 W
Speed 3 90 W
Maximum pump head: 6 m
Maximum pump capacity: 4,5 Ltr/Min
8.2 The double pump station must always be mounted at a level that is lower than the
panels so that no steam may penetrate the expansion vessel in case of stagnation.
Stagnation occurs when the solar panels have heat energy which is not needed
by the system and the panels stagnate at around 180° Celsius. If the expansion
vessel is mounted at the same level or at a higher lever than the panels, an
anti-gravity loop must be installed.
8.3 The double pump station is supplied with the two temperature gauges (ow pipe and
return pipe) with pre-tted ow gauge. On the return pipe is a pre-tted the safety
pressure relieve valve with tapping (RP 3/4’’), a pressure guage and a G 3/4”
connection for the expansion vessel.
8.4 Never ush the solar system with water.
8.5 The double pump station is not suitable for direct contact with swimming pool water.