8.6 Flow settings:
The ow regulator should be set to 0.5 to 1.0 litre per minute per panel. A three-panel
installation is set to a ow rate of 1.5 to 3 litres per minute.
How to read the ow setter:
8.7 Pressure settings:
The maximum pressure is 6 bar. Once the system is pressurised keep the pressure
between 3 – 4 bar. With higher pressure inside the system, the glycol/mix will not
evaporate until temperatures of around 120°Celsius are reached. Pressurisation
therefore helps to prevent glycol degradation and enables more useful heat energy
to be applied.
8.8 Maintenance:
The double pump station does not require maintenance. It is fully controlled by the
digital controller. The customer should do a visual check every month for leaks,
signicant different readings on the temperature gauges and readings on
digital controller, pressure drop below red line on the pressure gauge can indicate a
leak on the system. The customer should be informed that uctuations in pressure
readings while the system is operating are perfectly normal. In case of any
unexpected changes, the customer must contact the installer immediately.
Note: A competent solar engineer should service the system 3 years after install, and
then every 2 years there after.